Hot water does not come:one cause could be water pressure, or an excessive flow of cold water.

Typically, the main defendant is the boiler, but there are no problems related to limestone in filters, sinks and showers, or in the flexible under narrow and occlusive sinks.

Excluding the boiler block, we list the most common causes:

  1. Limestone in pipes:If the pipes inside or outside the boiler are occluded by limestone, the hot water does not come hindered by incrustations.The most obvious solution seems to be a chemical wash.
    It is always recommended to try first with acounter-washingwith only water to verify that there are no stones or scales that hinder the flow.
    Of course, a good upstream filter and an anti-scale water system can reduce inconvenience.
  2. Abnormal operation exchanger:if the water does not flow well in the boiler exchanger there is insufficient hot water production.Locked exchangerThe cause is often limestone that quickly forms inside.
    The solution is either in the washing or in the replacement and this obviously involves costs not cheap.
  3. Three-way valve damaged or encrusted:to be taken into account if it is noted that hot water does not come to the taps or shower at the same time as heating.The valve diverts the flow of water from the radiators to the hot water exchanger.
    If it is damaged, it is no longer able to divert the liquid correctly, so it does not heat up the water.
    The problem ison the primary circuit, replacement is the quickest solution but sometimes you can try in its cleaning or repair (but few do it because it is anti-economic and not always find the pieces to do so)
    It is recommended to fill the heating system with treated water by chemical conditioning (usually polyphosphates).
    This will avoid additional limestone in the circuit, it is also recommended to clean the entire primary circuit with suitable chemical solutions.
  4. Poor Water Pressure:a boiler has the function of heating the water, both to supply the taps and radiators.
    The boiler heats the water when it "understands" that you have opened a tap and does so by monitoring the "pressure" of the water.Washing radiator pipes
    When the entire boiler plant has low pressure, electronics can no longer understand if you are asking for hot water and therefore has repercussions on general performance and hot water is not supplied.

How to figure out if there are problems with the sanitary hot water exchanger or circuit

The pressure of hot water coming out of the taps should be almost the same as the cold pressure.

If this does not happen and the hot water is much lower, a chemical washing is required at the boiler.
If after hot water does not go out with the right pressure, perhaps it is time to assess whether to proceed with the chemical washing of the whole pipe, however, starting from the careful cleaning of the taps (they could be occlusive!) and their flexible if present.

As with the passing of time the metal pipes, especially those of copper and galvanized iron, in contact with the water rich of limestone inevitably are covered with deposits and calcareous incrustations, thethe chemical washing of the water pipe, circulating, through external pump, a specific acid solution disintegrating, allows the removal of deposits of limestone and oxides formed within the pipe.

Caution: the pipes, if completely obstructed, cannot be treated because the disincroment acid fails to pass.
It is important to intervene before the collapse of the passages.

Chemical washing can be carried out, as well as hot water pipes, even cold water pipes to eliminate oxides and impurities.

WARNING: DangerBy removing the limestone from the old pipes you candamage or damageopen holes kept closed by limestone.
Here's the dilemma: Try cleaning with the risk of failure or wait for complete closure of the implants?

 

problem-solutionKT300

Kalko Tronic solution

Kalko Troniccertainly does not do miracles but in many cases has allowed the recovery of pipes without the use of aggressive acids.

The water treated by Kalko Tronic gradually releases part of the anti-limestone effect in the pipes that tend to break off.
The greater the intensity of treatment, the more evident is the disacrystant effect.

If it is too intense it can cause partial occlusions.

Treatment can be "adjusted”.
Many condominiums and dwellings have benefited from a Kalko Tronic period (more or less long) with reduced power by progressively improving both the pressure and the overall hygiene of the plant while avoiding expensive hydraulic renovations.

In some cases the Kalko Tronic treatment is done more effectively.

The elimination of limestone, in cases where there is evident bacterial contamination, is more important than the risk of occlusion.

Being porous, limestone protects bacteria and encourages the formation of biofilms that must be removed quickly to reduce serious problems such as Legionella.
The most risky plants are always the subject of a preventive study where the technical office compares with both the planter and the property in order to find the most suitable solution.
After the first treatment period, Kalko Tronic maintains efficient implantation.
Many of our customers have already enjoyed 10-15 years of "water" without making expensive maintenance or renovations.

Our suggestion is therefore to prevent chemical washing with the installation of an electronic antiscale system Kalko Tronic
It could be the ideal system for you to safeguard your economy but also your health.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare

Your Shopping Cart

Close