Polyphosphates, filters, boilers... the jungle of regulations and concerned customers

polyphosphate

Posted on 27/06/2018 – Updated May 2025(Reading time: 4 minutes)

Water regulations: we make clarity

One of the most widespread concerns is the fear of not being in compliance with regulations. There is often a feeling that misleading information is spread, sometimes with the sole objective of "making a cashier".

It is important to know that water is regulated by two fundamental regulations, different from each other according to the use that it does:

1 – POTABLE WATER

Water of the aqueduct isalways drinkable. The minerals contained in it are useful to our health and no one can obligate its treatment.

Drinking water must be such cold and hot and the reference legislation is D. Lgs. 31/2001.

Those who use a softener must pay particular attention to the calibration:

  • the hardness should not descendunder 15 °f(French grade)
  • the sodium content after treatmentmust not exceed 200 mg/l

Those who use sodium water to cook should consider that sodium content is greater than those who do not use sweetener, especially for the preparation of pasta, soups and the like.

In addition, incorrect or uncontrolled calibration can make water aggressive and therefore no longer drinkable.

It should be remembered that the two limits (hardness and sodium)do not exclude each other: in the presence of very hard water, it is possible to exceed the sodium limitfirstto reach the 15thf.

In this context,Kalko Tronicrepresents an effective solution to save space, money, technical problems and health protection.

 

2 – AQUA IMPIANT TERMIC

The water ofclosed boiler circuit, of the heating system and that used for the production of sanitary hot water must betreated properlyto maintain high efficiency and quality of the plant.

Reference regulations

  • DM 59/2009
  • DM 26/06/2015 (which partially integrates and replaces the previous)
  • UNI 8065 (update of 18/07/2019 and later)

TheUNI 8065establishes that:

"The heating systems and those aimed at the production of sanitary hot water must be equipped with an adequate chemical conditioning of water".

What are the decrees, in short, for the thermal system?

  • It isalways mandatorythe treatment ofchemical conditioning, regardless of hardness.
  • For plants withpower exceeding 100 kWandwater hardness >15 °f, asoftening of plant waterAccording to UNI 8065.

Basically:

polyphosphate

all the new boilers provided apolyphosphate dispenserfor the load of the plant
over 100 kW it is also necessarysofteneror an equivalent cartridge (in often small condominiums)

This water becomes"technical"in the closed circuitis not the one that comes to taps and showers.

 

 

COMMON PROBLEMICS of polyphosphates... the new UNI standard (2019) says they are not adequate, so what to do?

UNI 8065 (2019) indicates thatpolyphosphates are not effective in closed circuits.

Common problems of polyphosphates

  • very fast consumption (even 1–2 weeks)
  • risk of encrustations if the dispenser is not recharged with constancy
  • possibleIntasation of the exchangerif the product is used before complete solidification
  • a solidified polyphosphateIt's not distractable→ replacement of the exchanger

We recommendpolyphosphate in crystals, more expensive but safer.

Health problems

The excessive use of polyphosphates is of concern, since their influence on health is not yet entirely clear. This is why use is recommendedonly on the thermal system and not on drinking water.

However, the UNI 8065 standard (point 6.4.2.1) states thatare not effective in closed circuits.

The legislation therefore suggests the use ofstabilizers of hardness, remembering that under 100 kWsoftening is not mandatory

For specific cases it is always advisableconsult the boiler service centre.

Attacher and regulations: are they in order?

It is essential to distinguish:

Drinking water – Legislative Decree. 31/2001

  • hardness ≥ 15 °f
  • sodium ≤ 200 mg/l

Thermal water – UNI 8065

  • treatment required if hardness >15 °f
  • obligatory softeningonly above 100 kW
  • hardness normally brought to 7–8 °f
  • necessaryanti-corrosive

The sweetenercan not manage at the same timedrinking water and technical water.

Kalko Tronic and legislationKalkoTronic and regulations

The systemKalko Tronicacts ondrinking water (hot and cold), protecting:

  • heat exchanger

  • household appliances

Before 2019 the obligation of polyphosphate dispenser on each boiler was foreseen. After 2019 it is appropriatecheck with the assistance centre.

For those who use a dispenser, a model withby-pass, to be able to exclude it if necessary.

 

Kalko Tronic will maintain efficient heat exchangerbut above all you will have water treatedMA ANCORA POTABILE, with or without polyphosphate dispenser.

 

Technical Office Kalko Tronic

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare

Your Shopping Cart

Close