Dot Dot Dot

Brief Tutorial on Kalko Tronics equipped with WiFi system

Home automation today requires you to have everything under control through your own internal home network or simply via your smartphone.
Below is a guide to better check how to use Kalko Tronic WiFi systems and in the absence of it read the spies correctly on board.

In the absence of access to the KT-WiFi some useful information on LEDs on board

The LEDs on the card are diagnostic, the WiFi module is located on the right side.

In some older models it may not be present, but you can buy it later.

LED description (similar to all Micro / Home Series models):

DL5: (Red) Voltage presence on power channels (Vpower)
DL6: (Green/Yellow) Voltage presence 1 Microprocessor
DL7: (Arancio) Voltage presence 2 Microprocessor
DL8: (White/Blue)LAMPINGMicro Processor Active
–
DL4-DL1: (BLU) Working channel presence: if the plant is on
–
DL10: (RED) Alarm presence (when it's on sounds Buzzer)
DL9: (Yellow) Active cooling fan

 

MORSETTI/CONNETTORS IN BOARD

The system has extra clamps compared to the manual.

JP3= Forced shutdown connector (Standby): printed a G (Ground) and B (Block) on the screen.
Used in special conditions, for example it can be switched off by another Kalko Tronic (Digit) machine if necessary.
It is located next to the reset button and the flashing white led.
JP4 (JP5 in many plants since 2024)= Connector for cooling fan operation
The clamp can be divided into 2, a standard forced insertion connector (Jp4) and a screw clamp (pictured the orientation of + 12 Volts DC)
In case of incorrect insertion of the cables the fan will remain stationary (security against polarity reversals on fan board)
JP6= Forced drive jumper of cooling fan.
In some models there is, for testing, the JP6, is a bridge, if it is closed: the fan will turn continuously.

You find it next to the WiFi, sometimes near the connector itself.
In the most recent models it has been eliminated, to do the test you can turn off and turn on the machine, a start of about 1 second of the fan will be done after the control of the treatment bands.

Buzzer= Sound alarm signal.
It allows the user to understand immediately when the system has a serious problem.
The buzzer has an adhesive on top of the sound dispenser that attenuates its audio, in case of noisy environments or distant areas it is possible to remove it to increase its effectiveness.
In case of pre-maintenance alarm it is possible to stop it temporarily by pressing the reset button for 5 seconds and the confirmation of acceptance of the command will take place via 2 consecutive beeps, in recent machines just pass the old R-Fid, you will have the same break as the alarm.

Jp4(since 2024 Rfid series): a new 3-room clamp is introduced to insert a dedicated counter, available only for RFID versions.

JP7(present on most models): This is the programming port of the system but only from 2024 with RFID models you can operate to upgrade the software of the machines by purchasing its programmer going to exploit the features that over time will be added making the machines up to date and performing.
This function can only be performed by authorised service centres.

WiFi: WiFi connection for diagnosis and online system guidance.

Sound Alarm Guide


It is also present on board the WiFi system available to the customer

1 Beep every 30 minutes
Pre-awakening: assistance is due (less than 1 month at the annual deadline)
What to do: Ensure assistance during the specified time.

1 Beep every 10 seconds
Expired maintenance.
What to Do: You must alert the Help Center, you can disable the alarm temporarily (7 days) by pressing the Reset button for 5 seconds.

1 Beep every 5 seconds (home and Rfid Cap systems)
The plant may have detected a problem on the treatment bands and is warning that a technician needs control.

Beep continuous alarm
The continuous alarm can intervene in some important cases:

– Burned voltage fuse

What to Do: Check the fuse and possibly replace it with an equivalent (see manual), warn your Help Center.

– Alarm Temperature

The plant has reached a limit temperature of operation
What to do: Try to keep the machine off for a short time, or create a shade field if exposed to the sun; if the problem persists contact the Help Center.

– Urgent maintenance

The system entered the alarm before risking electronic damage.
What to do: contact the Help Center.

– Voltage beyond maximum permissible (in models since 2025)

The system entered the alarm signaling the network anomaly, signaling a voltage over 250 Vac.
What to Do: contact the Help Center and turn off the machine if such alarm remains or buy a network stabilizer and connect it to KalkoTronic.

– Fasce with criticality or disconnected cables

Check the cables of the bands and check when the last maintenance has been performed, it is also important to check that there has been no condensation: the latter may have ruined the treatment bands. In case of need it is recommended to create an extra cover on the hydraulic part so as to reduce the condensation problem.

To connect to the wifi there are different modes.


The first is the default direct connection in each Kalko Tronic, looking for the wifi connections available you will find the SSD:

KT-DIRECT-Axxx – Password default : kt123456

The connection is customised according to the serial number of the device.

There are 2 connection modes for access to instructions.

1st MODE: CLIENT DIRECT CONNECTION


This connection is just indicated and once connected to your smartphone you can access the system page by typing on the address bar as follows:

192.168.1.200

You will access the KalkoTronic information page

2nd MODE: CONNECTION TO CASA NETWORK


You have to turn off the Kalko Tronic system, press the reset button and turn on the system holding it down for about 10 seconds.
Kalko Tronic after about 10 seconds will light the 4 blue leds of the power and will emit beeps, after which should flash 1 time also the WiFi module.
In the next generation plants from 2025 onwards, check and then count the 10 seconds to display the WiFi reset procedure.
At this point you will find on your smartphone the request for configuration with an SSID called

KT config AP

You may ask for the password, if you require that standard kt123456
In this case, configure the SSID vs. also as indicated by the configuration manual.
By accessing from vs. pc you will have to put the internet address set for vs. Kalko Tronic, by default is 192.168.1.200 but you can change it.

Downloads


You can download the additional instruction file for KT Micro Plus WiFi here for models up to serial A 267:

REGULATION INSTRUCTIONS KT MICRO PLUS-WiFi REGULATION INSTRUCTIONS KT MICRO PLUS-WiFi

You can download the additional instruction file for KT Micro Plus/Plus Power/Hyper WiFi here for later models.
Although systems have evolved over time we have maintained the main operational characteristics.
You will find some differences for adding new features but connection and consultation operations are the same:

REGULATION INSTRUCTIONS KT MICRO PLUS-WiFi 1.2 REGULATION INSTRUCTIONS KT MICRO PLUS-WiFi 1.2

In case of difficulty the technical office is available.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare

Your Shopping Cart

Close